Table 2

Expected total width of the 95% CI for the sensitivity, given the sensitivity of test (rows) and the number of ‘positive’ samples (columns)

Number of positive samples
50100200400600
Assumed sensitivity of test0.850.220.150.100.070.06
0.90.190.130.090.060.06
0.950.140.100.070.050.04
0.990.090.060.040.020.02